Artillery Sidewinder X2
Power consumption analysis, verified wattage measurements, and interactive electricity cost calculator for the Artillery Sidewinder X2.
Interactive Electricity Cost Calculator
Adjust printing hours and your local energy tariff to estimate daily, monthly, and annual operating costs.
US Average: ~$0.16 • EU: ~€0.25 - €0.35 • UK: ~£0.28
Pre-filled from measured average operating telemetry.
Hardware & Build Specifications
- Manufacturer
- Artillery
- Motion Kinematics
- Bed Slinger FDM
- Build Envelope
- 300 x 300 x 400 mm
- Bed Construction
- AC Heated Tempered Glass Bed
- Typical Peak Draw
- 600W
Frequently Asked Questions
The Artillery Sidewinder X2 consumes an average of 160 Watts while printing. Operating it for 8 hours uses approximately 1.28 kWh, costing roughly $0.20 at standard rates ($0.16/kWh).
During the initial 3 to 6 minute warmup phase, the heated bed and hotend run at 100% duty cycle to reach target temperature as quickly as possible. Once stabilized, power drops to the ~160W average.
When powered on and in standby (display on, mainboard fans idle, heaters off), it consumes roughly 5W to 15W of background electricity.
Yes. Because average running draw is only ~160W, a standard 500Wh portable power station or 1000VA UPS battery can easily sustain printing for 3 to 5 hours through power outages.
Yes. Maintaining a heated bed at 100°C-110°C for engineering materials requires more continuous thermal power than printing PLA at 60°C, increasing average power draw by roughly 40W to 80W.